เป็นเบรกเกอร์ที่ใช้งานง่าย ติดตั้งง่าย ราคาย่อมเยาว์ แต่ประสิทธิภาพการป้องกันสูง ตัวเบรกเกอร์สีดำ มีคุณสมบัติคล้ายกับรุ่น EasyPact CVS กระแสไฟฟ้า 100 – 400A มีทั้งแบบ 1, 2, 3 และ 4 Pole
Features
The EasyPact CVS range is the easy choice for quality and value. Designed to meet the requirements of the majority of common protection applications in medium-sized buildings, the new EasyPact CVS circuit breakers deliver a level of performance and cost-saving functionality that is unusual in their price range. Features:
- Rated current from 100 to 630 A
- Breaking capacity from 25 to 50 kA at 400/415 V
- 3- and 4-pole versions
- 3 Frame sizes
- Thermal-magnetic and electronic protection available for the entire range
- Extended, adjustable thermal protection from 0,7 to 1 times (TMD) or 0,5 to 1 times (electronic) the rating of the trip unit
- Common accessories and auxiliaries with other Schneider Electric MCCB offers
- Suitable for isolation
- Earth-leakage protection achieved by installing a Vigi module or a Vigirex relay
- Switch-disconnector versions also available
- Compliance with IEC 60947-2
- Certifications: GOST, CCC, CCS
Benefits
Get the performance you need, at a cost-effective investment, with the quality you demand:
- Exceptional feature set including extended current limiting capacity and adjustable thermal protection
- Simplicity of selection, purchasing, stocking and installation
- IEC compliant, internationally certified offer, delivers Schneider electric commitment to quality
Product Range
100AF
– EZC100AF number pole 1-4 Pole
-Rated Current 15,16,20,25,30,32,40,45,50,60,63,75,80,100A
– Short circuit breaking capacity (Icu) (400-415Vac) 18,5,30,7.5,10,15,30kA
250AF
– EZC250AF number pole 2-4 poles
– Rated current 100,125,150,160,175,200,225,250A
– Short circuit breaking capacity (Icu) (400-415Vac) 18,25,36kA
400AF
– EZC400AF number pole 3-4 poles
– Rated current 320,350,400A
– Short circuit breaking capacity (Icu) (400-415Vac) 36,50KA
100AF
250AF
Number of poles | 2Poles | 3Poles | ||
Short circuit breaking capacity (Icu) |
30 kA (@ 400/415 V) |
18 kA (@ 400/415 V) |
25 kA (@ 400/415 V) |
36 kA (@ 400/415 V) |
100A | EZC250H2100 | EZC250F3100 | EZC250N3100 | EZC250H3100 |
125A | EZC250H2125 | EZC250F3125 | EZC250N3125 | EZC250H3125 |
150A | EZC250H2150 | EZC250F3150 | EZC250N3150 | EZC250H3150 |
160A | EZC250H2160 | EZC250F3160 | EZC250N3160 | EZC250H3160 |
175A | EZC250H2175 | EZC250F3175 | EZC250N3175 | EZC250H3175 |
200A | EZC250H2200 | EZC250F3200 | EZC250N3200 | EZC250H3200 |
225A | EZC250H2225 | EZC250F3225 | EZC250N3225 | EZC250H3225 |
250A | EZC250H2250 | EZC250F3250 | EZC250N3250 | EZC250H3250 |
400AF
Number of poles | 3Poles | |
Short circuit breaking capacity (Icu) |
36 kA (@ 400/415 V) |
50 kA (@ 400/415 V) |
320A | EZC400N3320N | EZC400H3320N |
350A | EZC400N3350N | EZC400H3350N |
400A | EZC400N3400N | EZC400H3400N |